A Simple Model for Fault-Charged Hydrothermal Systems

Basic Information
Author: Bodvarsson, G. , Miller, C.W. , Benson, S.M.
Description:A simple two dimensional transit computer model for fault-charged hydrothermal systems. The model can be used to analyze temperature data from fault charged hydrothermal systems, estimate the recharge rate from the fault, and determine how long the system has been under natural development. The model has been tentatively applied to the hydrothermal system at Susanville, California. LBL Pub. No. LBL-12869
Publication Date:
Author Contact Information
Distributor Contact Information
Organization Name: Bureau of Economic Geology, University of Texas at Austin
Street: University Station, Box X
City: Austin
State: Texas
Zip: 78713
Phone: 512-471-1534
Geographic Extent
North Bounding Latitude: 41.2142054935
South Bounding Latitude: 39.8448212866
East Bounding Longitude: -120.007165791
West Bounding Longitude: -121.743005635